Localised corrosion of electric resistance welds of austenitic stainless steel in sea water

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

An investigation was conducted on prematurely failed titanium stabilised austenitic stainless steel tubes of a heat exchanger used in sea water service. The tubes were longitudinally welded using the high frequency electric resistance welding technique. The investigation showed the failure to be due to pitting and crevice corrosion at the weld. The attack occurred at discrete sites and the deposits inside the pits were rich in chromium and iron. The corrosion of the tubes was attributed to depletion of chromium and molybdenum from the austenite phase. This depletion was ascribed to coarsening of the delta ferrite phase as a result of high heat input during welding.

Original languageEnglish
Pages (from-to)45-49
Number of pages5
JournalBritish Corrosion Journal
Volume27
Issue number1
DOIs
StatePublished - Jan 1992

Funding Agency

  • Kuwait Foundation for the Advancement of Sciences

Fingerprint

Dive into the research topics of 'Localised corrosion of electric resistance welds of austenitic stainless steel in sea water'. Together they form a unique fingerprint.